2 _ Safety Instructions
WHILE SERVICING
• Checkifthepowerplugandoutletaredamaged,attened,cutorotherwisedegraded.
Iffaulty,replaceitimmediately.
Failingtodosomayresultinelectricshockorre.
• Completelyremoveanydustorforeignmaterialfromthehousing,wiringandconnectionparts.
Thiswillpreventariskofreduetotrackingandshortsinadvance.
• Whenconnectingwires,makesuretoconnectthemusingtherelevantconnectorsandcheckthattheyare
completelyconnected.
Iftapeisusedinsteadoftheconnectors,itmaycausereduetotracking.
• MakesuretodischargethePBApowerterminalsbeforestartingtheservice.
Failingtodosomayresultinahighvoltageelectricshock.
• Whenreplacingtheheater,makesuretofastenthenutafterensuringthatitisinsertedintothebracket-heater.
Ifnotinsertedintothebracket-heater,ittouchesthedrumandcausesnoiseandelectricleakage.
AFTER SERVICING
• Checkthewiring.
Ensurethatnowiretouchesarotatingpartorasharpenedpartoftheelectricalharness.
• Checkforanywaterleakage.
Performatestrunforthewashingmachineusingthestandardcourseandcheckwhetherthereisanywater
leakagethroughtheoorsectionorthepipes.
• Donotallowconsumerstorepairorserviceanypartofthewashingmachine
themselves.
Thismayresultinpersonalinjuryandshortentheproductlifetime.
• Ifitseemsthatgroundingisneededduetowaterormoisture,makesuretorun
groundingwires.
(Checkthegroundingofthepoweroutlet,andadditionallygroundittoametallicwater
pipe.)
Failingtodosomayresultinelectricshockduetoelectricleakage.
[Runningagroundingwire]
- Twistagroundingwire(copperwire)twoorthreetimesaroundthetap
- Ifyouconnectthegroundingwiretoacopperplate,buryit75cmundertheearthina
placewithalotofmoisture.
Donotconnectthegroundingwiretoagaspipe,plasticwaterpipeortelephone
wire.Thereisariskofelectricshockorexplosion.
75 cm
Copperplate
WARNING
Grounding
terminal
WARNING
WD6500K_7-8-9-11kg_1400rpm-SM.indb 2 2018/11/9 9:52:44