20 _ Removal and Reassembly
Part Figure Description
Disassembling the
Tub
1. Removethe2screwsxingGUIDE-WIRE,6
screwsxingFRAME-PLATE(U).
2. Removethe6boltsxingWEIGHTBALANCER
and then pull it towards with caution.
3. Removethe4boltsxingDAMPERtotakeASSY
TUB out.
4. Remove all wire and hose connected the ASSY-
TUB.
5. Open the cap of SPRING-HANGER to take ASSY-
TUB out.
6. Lift the ASSY-TUB with two people carefully with
holding SPRING-HANGER.