32 _ Troubleshooting
No. Information Type
Information
Code
Causes Corrective Actions
10 WaterLeakage
LC
LC1
- Heaterengagementfault.(outofplace)
- Theairhoseisoutofplaceandwaterleakageoccurs
duringthespincycle.
- Thetubbackatthesafetyboltsxingpartisbroken.
- Waterleakageoccursatthefrontwithfoaming
becauseoftoomuchdetergent.
- Waterleakageoccursbecausetheconnectinghoseto
thedetergentdrawerisconnectedincorrectly.
- Thedrainpumpltercoverisengagedincorrectly.
- Waterleakageoccursatthedrainhose.
- Theductcondensingholdingscrewsareworn.
- Thenozzle-diaphragmisengagedintheopposite
directionortherubberpackagingisomitted.
- Waterleakageoccursbecausethescrewsthat
holdthetubbackandfrontinplacearefastened
incorrectly.
- Theleakagesensorisfaulty.
•CheckWaterLeakage.
•DVCASEforeignmaterialoccurs.
•Leakageoftheproductinsidethe
hoseandpartsmoldedproblem.
11 OVER FLOW
OC
OF
- Waterissuppliedcontinuallybecausethewaterlevel
detectiondoesnotwork.
- Becausethedrainhoseiscloggedandthereisan
injectionerror(atanarrowsection),thewaterlevel
detectiondoesnotworkandwaterissupplied
continually.
- Waterissuppliedcontinuallybecauseoffreezingor
becausethereisforeignmaterialinthewatersupply
valve.
- Thismayoccurwhenthesensorisfaultyorthe
pressuretubeisblockedordamaged.
•Waterlevelsensorfault.
•Freezingbywinterseason.
12
Temperature
Sensor
TC1
- Thewashingheaterinthetubhasanerror.
(Contacterror,temperaturesensorfault)
- Theconnectorisconnectedincorrectlyoris
disconnected.
- Ifthewaterlevelsensoroperateswithoutwater
becausethewaterisfrozenorforanyotherreason
andthetemperaturesensorengagedatthebottom
topreventoverheatingforthewashingheaterdetects
atemperatureof100to150˚C,thewashingmachine
turnstheinputpoweroff.
•Washingtemperaturesensor
check.
•Drytemperaturesensorcheck
•Drycondensingtemperature
sensorcheck.
•ProblemscausedbythemainPCB
fault.
•Problemscausedbythefreezing
inwinter.
TC2
- Thetemperaturesensorfortheductassyfanhousing
isfaulty.(Asensorfaultsuchasaninternalshort-
circuitorwiredisconnection)
- Theconnectorisoutofplaceorhasacontacterror.
TC3
- Thisoccurswhentheductcondensingtemperature
sensor is open.
- Thisoccurswhentheductcondensingtemperature
sensorhasawiredisconnectedorisshort-circuited.
13 UNBALANCE UB
- Aslaundrycausesthiserror,checkthelaundry.
- Findthereasonfortheunbalanceandsolveitas
directedintheusermanual.
•Thisoccursbylaundry.
36 / 45 35 / 43 36 / 45