4.Troubleshooting
ErrorCode
S6–3123
Errormessage
ThisIPaddressconictswiththatofothersystem.Checkit.
Symptom
Networkhassomeproblem.(IPaddressconictswiththatofothersystem./Communicationerror/Thereisno
responsewhencheckingthepingtest.)
Troubleshootingmethod
Changethemachine’sIPaddress.
ExecutetheSamsungEasyPrinterManagerprogram.(DevicesettingNetworkIPaddress).Changethe
IPaddress.
IncaseofDHCPorBootp,rebootthemachinetoreceiveanewIPaddress.
ErrorCode
S6–3210
Errormessage
NetworkFailure:#S6-3210.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
Departmentsalongwithwirelessmoduleisabnormal.
Troubleshootingmethod
1)Turnthemachineoff,andthenturnon.
2)CheckthesettingisproperAPsettingofwirelesslanandprinterconguration.
4-34Copyright©1995-2013SAMSUNG.Allrightsreserved.