EasyManuals Logo

S&P TR90 User Manual

S&P TR90
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
TR90-Series Due to continuing product development, specications are subject to change without notice. © 2018 S&P
132104_002 Revised 8/2018 Page 7
Service Parts
www.renewaire.com (800) 627- 4499 support@renewaire.com
Maintenance Requirements
Keep your ERV performing at its best by cleaning it as described
below:
RISK OF ELECTRIC SHOCK OR INJURY.
Before servicing or cleaning the unit, unplug the
unit line cord.
Make sure unit is not running before opening its
door. Blower wheels are sharp and can cut.
Do not disable the interlock switch: it is there for
your safety.
Service lters regularly:
Service lters every three months when the unit is in regular use
or as needed to keep them reasonably clean.
1. Release cam latches and carefully swing access door open.
Remove the door by sliding to one side.
2. Remove lter clips and pull out the lters.
3. Vacuum core and lters with a hose attachment.
4. Re-install lters and lter clips, (see above).
5. Re-install door, and fasten cam latches.
NOTE: The lters should be replaced after they have been cleaned
several times. The primary contact for replacement lters for
your S&P unit is the installing contractor. As an alternative, you
may wish to produce your own lters.
Filters may be cut from a sheet or roll of ¾” - 1” rm, spun
polyester lter media or material, similar to the existing lter in
the residential unit.
The size of each lter (2 required per unit) is as follows:
90-Series - 9 ½” x 10 ½”
NOTE: Filters must be used or the face of the energy exchange
core will become blocked by dust. The lters supplied in the
unit are usually able to keep the energy exchange core clear
for many months. Finer lters can be used but must be cleaned
more often.
Clean the face of the energy exchange core yearly:
1. Remove the lters (see above).
2. Vacuum the exposed faces of the energy exchange core with
a soft brush attachment.
3. After servicing the lters, re-install them (see above).
4. Vacuum out dust from the rest of the unit case.
Dust collects only on the entering faces of the energy exchange
core. The interior of the energy exchange core stays clean even
if the core faces are dust covered.
DO NOT WASH THE ENERGY EXCHANGE CORE.
Clean only as described above. The energy exchange
core can be replaced but is expensive.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the S&P TR90 and is the answer not in the manual?

S&P TR90 Specifications

General IconGeneral
BrandS&P
ModelTR90
CategoryController
LanguageEnglish

Related product manuals