11 / 32
7) Speed switching function
The operation pattern can be switched by powering ON/OFF the external signal [in3 Input] in
the operation mode (“A” mode).
Operation mode
Operation patten No.
Display according to
external signal
out1
out2
out1
out2
Display according to
panel setting
Invalid
Invalid
P1
P2
in3 input status
OFF
ON
OFF
ON
Patterns “P3” and “P4” shown on the display cannot be controlled by external signals.
a) Operation pattern switching method for each operation mode
(1) “A” mode
Turn ON/OFF the external signal [in3 Input].
(2) “n” mode
Turn ON/OFF the external signal [in3 Input].
Switch to P1/P2 in the panel setting.
b) Amplitude adjustment method for each operation pattern
The amplitude is adjusted in the n mode.
When the Func key is pressed 3 times, the PAT lamp blinks, displaying [out1].
Each time the Freq key is pressed, the display changes in order of P1 P2
P3 P4 out1. When the Freq key is pressed, the display changes in the
reverse order of the above.
Press the Set key when P2 is in display (to adjust the amplitude in the operation pattern
2).
To switch the operation pattern to No. 2 according to the external signal, press the Set
key when out1 is in display to turn [in3 Input] into the ON status.
The PAT lamp lights up, and the voltage% is displayed.
Adjust the amplitude by referring to 8. Operation and Amplitude Adjustment Method.
When the adjustment of both the patterns 1 and 2 is completed, start operation in the “A”
mode. In the “A” mode, the setting is forced to be switched to the external signal.
[Internal circuit]
Example of circuit to be
arranged by customer