10. “io” Mode Setting Function
This Controller can switch the control target of the overflow sensor input [in2 Input].
The functions that the “io” mode setting can perform:
Switching of the io mode
Initialization of the set data [Reset to the factory setting]
Function
Control target
io01
Controls the feeder output in [in2 Input]. [with overflow stop] (factory setting)
io02
Does not control the feeder output in [in2 Input]. [without overflow stop]
99
Initializes the set data [Resets to the factory setting].
1) “io” mode switching method
(1) When the power supply to the Controller is OFF, power ON the Controller by pressing both
the Vol key and the Freq key together.
(2) The data display area displays “io01” to start the Controller.
If the Controller starts in a normal manner, redo the above (1) and (2).
(3) Press the Freq key to select the io mode to be used.
The display switches io01 io02 99 io01 in this order.
When the Freq key is pressed, the display area switches them in the reverse order.
(4) Press the Set key long for 2 sec to start the controller in a normal manner in the selected “io”
mode.
For example, when “io02” is selected, “io02” is displayed when the “io” mode is displayed
upon powering ON the controller.
The motion in each io mode is identical to the motion shown in the following time chart:
When the io mode is io01 When the io mode is io02
Feeder output
When the “io” mode is io02, the parameter
Nos. 0E and 0F become invalid.
Feeder output