(4)FUNC Locks/unlocks the magnification change setting.
“A” mode: Enabled and displays only in the amplitude control setting (0u: 1) and the remote
unit setting (0L: oF).
Loc: Locks. (The speed magnification cannot be changed. Displays “「 ̄」” in the decimal
point section of the voltage setting.)
uLoc: Unlocks. (The speed magnification can be changed. Displays the value of the decimal
places of the voltage setting.)
7-4. Preparation for Operation
Before powering ON the Controller, recheck the model, specifications, the drive rating and power
voltage of the Controller to confirm no discrepancy, and also recheck the connections to confirm
no wrong connection. Particularly when external signal is used, be careful not to mistake the
polarity.