USER MANUAL
3.11 PARAMETERS DESCRIPTION
Parameters can be broadly classified into (A) early warning parameters, (B) regional early warning
parameters, (C) parameters related to equipment and applications such as MQTT and firmware
updates. Parameter settings are based on vAlert8.cfg file i.e. the main configuration file of the unit.
(Engineers Only)
Please refer to Palert Manual for further information on many of these parameters.
3.11.1 EARLY WARNING PARAMETERS
[PALERT_LOCAL_MODE]
SERIAL_NO
Serial number of the unit normally should not be
changed.
LCD_BACK_LIGHT_SECOND
15
SERVER_IP
Server IP:port. Can have up to 3 servers.
MOUNT_MODE (Palert+)
WALL
OR
NORTHWARD (Normally not used)
OR
EASTWARD
SERVER_STREAM_MODE_TAIWAN
1
SERVER_PASSWORD
Server authentication password for CEB mode.
CEB_SEND_TIMEOUT_USEC
5000
MSEEDFILE_VALID_DAY
90
MODE
The streaming packet format, TAIWAN or CHINA
mode.
CEB_MODE
Whether to adopt the China Seismological Bureau
protocol, YES / NO.
Station naming parameters for use with miniSeed file format especially