USER MANUAL
STATION_NET
Which network is the unit part of. E.g. NZ
STATION_NAME
Station name.
STATION_CH_NAME
Station channel name for central server, such as
HL.
STATION_CH_GEO_NAME
Additional name to handle areas
STATION_LOCATION
Station location for central server, such as 01.
STREAM_TRIG_PACKET
Sending trigger message or not.
STREAMING_IN_MSEC
Millisecond stream default 1000
SAMPLING_RATE
Sampling rate 50/100/200 sps.
VECTOR_INTENSITY
YES / NO
SPS_CH0
Samples per second Channel 0 Default 50
SPS_CH1
Samples per second Channel 1 Default 100
0SPS_CH2
Samples per second Channel 2 Default 200
FIR_MODE
Minimum phase filter (Only on low-pass filter) YES
/ No.
LPF
Low pass filter 10/20/40 Hz.
HPF
High-pass filter 0.1 / 0.3 / 0.5 / 1 Hz.
WATCH_TIME
Alert duration - seconds.
WARNING_TIME
Warning duration - seconds.
PD_TRIG_ENABLE
Use Pd threshold to trigger event YES / NO.
PD_WATCH_THRESHOLD
P-wave Pd displacement (cm) Alert threshold
Default 0.2