USER MANUAL
3.11.3 N OUT OF M SETTING
Note: Below are settings to add other Palerts for configuring 2 out of 3 system to eliminate the
possibility of false alarm (N out of M settings).
Currently N out of M is not implemented in Palert+ but only in PX-01 and Cube.
PALERT IP
Add 1 or multiple Palert or Palert+ IP.
MESSAGE PALERT
Which one will be the main Palert out of M
Starting from 0 M.
N WHERE N OUT OF M
N out of M Palerts, here add value for N.
M WHERE N OUT OF M
N out of M Palerts, here add value for M.
N OUT OF M IN SECOND
Acceptable time gap interval in secs, between the
triggered Palerts
N_OUT_OF_M_BY_MIDDLE
Event trigged while the number of trigged Palert +
greater than or equal to N.
The system in addition to providing local earthquake warning functions can also provide regional
earthquake early warning.
Alerts can be received using the public protocol (Common Alerting Protocol, CAP) earthquake early
warning messages.