MAINTENANCE
Prior to carrying out any intervention on the appliance, it must be
disconnected from the mains without fail.
Changing the coupling system:
When changing the couplings, make sure you adhere to the position of each component:
• flexible coupling (11) on the motor unit
• rigid coupling (12) on the blade holder.
IMPORTANT:
Motor end:
Turn the screw (13) counter clockwise to remove the flexible coupling (11).
Blade end:
Turn the screw (14) counter clockwise to remove the rigid coupling (12).
REMARKS: for N°37 versions prior to 2012, screw (13) must be turned clockwise to
remove the flexible coupling (11).
Loosening direction of fixing
screw, motor end: counter
clockwise
Loosening direction of fixing
screw, jar end: counter
clockwise
4080045-7-8-9 G20E 10/15