EasyManua.ls Logo

Sanyo C4232 - Indoor Unit Major Component Specifications

Sanyo C4232
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 10 –
SM830078
(2) Major Component Specifications
(A) Indoor Unit
2. SPECIFICATIONS
DATA SUBJECT TO CHANGE WITHOUT NOTICE
MODEL No. XS4232
Source 230 - 208 V / 1 phase / 60 Hz
Remote controller (Accessory) RCS - 5PS4U
Controller P. C. B Ass'y CR - TS2432
Control circuit fuse 250 V, 3 A
Switch Ass'y SW - X363GS
Fan (Number … diameter) in. (mm) Turbo (1…19-9/32 (490))
Fan motor
Model SFG6X - 61A3P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High) rpm 6 … 560
Nominal output W 60
Coil resistance BRW - WHT : 71.1 , ORG - YEL : 22.7
(Ambient temperature 68 °F) WHT - VLT : 8.7 , VLT - PNK : 43.2
VLT - ORG : 13.3 , YEL - BLK : 54.32
Safety device
Operating temperature Open °F266± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 6 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows … Fins per inch 2 … 14.9
Face area ft.
2
(m
2
) 5.17 (0.48)
Panel
Model No. PNR - XS3632
Indicator Lamp Ass'y IND - XS3632
Auto louver motor MT8 - 3C
Auto louver motor … Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16,430 ± 8 %

Related product manuals