EasyManua.ls Logo

Sanyo C2462R - User Manual

Sanyo C2462R
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
– 1 –
SM830092
854648419200
KS2462R C2462R
CL2462R
Indoor Unit Outdoor Unit
SPLIT SYSTEM AIR CONDITIONER
TECHNICAL DATA
&
SERVICE MANUAL
FILE NO.
INDOOR MODEL No. PRODUCT CODE No. OUTDOOR MODEL No. PRODUCT CODE No.
KS2462R 854 019 00
C2462R 854 019 01
CL2462R 854 019 02
KS2462R / C2462R, CL2462R
REFERENCE NO.
SM
830092

Questions and Answers

  • T
    timothydickersonJul 30, 2025
    What to do if my Sanyo C2462R shows false results due to wiring problems?
    • G
      Glenda ShawJul 30, 2025
      If your Sanyo Air Conditioner is showing false results, it might be due to wiring or power supply issues. Here's what you should check: * Ensure the power supply wires are correctly connected to L1 and L2 on the 6P terminal in the outdoor unit. * Confirm that the inter-unit wiring (AC 230 - 208 V Line voltage) is correctly connected between the indoor and outdoor units. * Verify the voltage is within the specified range (±10 % of the rating) and that power is being supplied. * Inspect the lead wires and connectors in both the indoor and outdoor units. * Make sure the sheath of the lead wires is not damaged. * Check that the lead wires are firmly connected at the terminal plate. * Ensure that the wiring is correct.

Summary

Safety and Installation Precautions

Before Starting Installation

Crucial safety and operational guidelines to follow before installation begins.

Special Precautions During Installation

Key safety measures for wiring, transporting, installing, and connecting units.

Product Specifications and Performance Data

Operating Range Limits

Defines the operational temperature boundaries for the air conditioning system.

Unit and Component Specifications

Detailed specifications for the indoor, outdoor, and component parts.

Dimensional Data and Layout

Physical dimensions and installation layout information for the units.

Cooling Capacity Performance

Tables detailing cooling capacity under various operating conditions.

Performance Characteristics Charts

Graphical data on operating current, pressures, and air throw.

Refrigerant Flow Diagrams

Visual representation of refrigerant circulation paths within the system.

Installation and Electrical Procedures

Installation Instructions

Step-by-step guidelines and requirements for installing the air conditioner.

Electrical Data and Wiring Diagrams

Electrical characteristics, wiring diagrams, and power supply recommendations.

Unit Operation and Service Procedures

Processes and Functions Explained

Explanations of key operational modes like temperature control, dry, and freeze prevention.

Troubleshooting and Component Checks

Diagnostic procedures for identifying and resolving operational and component issues.

Refrigerant R410 A Handling and Tools

Precautions for R410A refrigerant, installation checklists, and specific tools.

Sanyo C2462R Specifications

General IconGeneral
Cooling Capacity24000 BTU/h
RefrigerantR22
Power Consumption2.5 kW
TypeSplit
Power Supply220V, 50Hz
Operating Temperature18°C to 43°C

Related product manuals