What to do if my Sanyo C2462R shows false results due to wiring problems?
- GGlenda ShawJul 30, 2025
If your Sanyo Air Conditioner is showing false results, it might be due to wiring or power supply issues. Here's what you should check: * Ensure the power supply wires are correctly connected to L1 and L2 on the 6P terminal in the outdoor unit. * Confirm that the inter-unit wiring (AC 230 - 208 V Line voltage) is correctly connected between the indoor and outdoor units. * Verify the voltage is within the specified range (±10 % of the rating) and that power is being supplied. * Inspect the lead wires and connectors in both the indoor and outdoor units. * Make sure the sheath of the lead wires is not damaged. * Check that the lead wires are firmly connected at the terminal plate. * Ensure that the wiring is correct.