9. ELECTRICAL DATA
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 - 208 V / 1 phase / 60 Hz
Rating conditions
A 0.38 - 0.37 0.90 - 0.90 8.8 - 9.6 10.1 - 10.9
kW 0.08 - 0.07 0.18 - 0.17 2.02 - 2.00 2.25 - 2.24
Full load conditions
A 0.38 - 0.37 0.90 - 0.90 11.1 - 12.4 12.4 - 13.7
kW 0.08 - 0.07 0.18 - 0.17 2.55 - 2.58 2.81 - 2.32
Starting amperes A 1 - 1 1 - 1 61 - 55 63 - 57
Electrical characteristics
Indoor model: KS2462R / Outdoor model: C2462R, CL2462R
Rating Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 95 °F DB
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 115 °F DB