EasyManua.ls Logo

Sanyo CLM1972 - Outdoor Unit Wiring; Wiring Instructions for Outdoor Unit Connections

Sanyo CLM1972
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
1
2
3
1
2
3
1
2
3
1
2
3
Indoor unit D
Indoor unit B
Indoor unit A
Indoor unit C
Ground
Power:
Single-phase,
230/208VAC 60HZ
Power switch
(not provided)
Outdoor unit A
Ter mi nal board
Label A
Inter-unit cables
#14 (not provided)
Ter mi nal board
Inter-unit cables
#14 (not provided)
Ter mi nal board
Label B
Label C
Inter-unit cables
#14 (not provided)
Ter mi nal board
Inter-unit cables
#14 (not provided)
Ter mi nal board
Label D
A
B
C
D
Power cable (not provided)
(#12: Less than 85 ft.)
# ... AWG (American Wire Gauge)
Be sure to perform grounding.
Attach a ground wire to either the
outdoor unit or indoor unit.
If there is a grounding terminal
inside the room, use the grounding
screw inside the indoor unit.
Be sure to apply the provided labels to both
ends of the inter-unit cables to prevent mis-
wiring. The units will not function if the wiring
connections are incorrect.
A is the indoor unit with
refrigerant tubing that is
connected to service valve
A (top) of the outdoor unit.
refrigerant tubing that is
connected to service valve
B (top) of the outdoor unit.
B is the indoor unit with
refrigerant tubing that is
connected to service valve
C (top) of the outdoor unit.
C is the indoor unit with
refrigerant tubing that is
connected to service valve
D (top) of the outdoor unit.
D is the indoor unit with
1 2
1 2 3 4 5 6 7 8 9 10 11 12
Power supply
(conduit)
Inter Unit
(conduit)
5-5. Wiring Instructions for the Outdoor Unit
G Be sure to correctly align inter-unit cables A, B, C and D.
G Use a dedicated A/C circuit for power.
G To make connections to the outdoor unit, remove the
inspection panel and tubing panel.
G Do not bring the inter-unit cables or power cable into
contact with tubing or service valves.
G Use outdoor unit cable fasteners and fasten the inter-
unit cables at the location where the cables are double-
sheathed.
G Arrange the wiring so that the inter-unit cables are con-
tained in the inspection panel and tubing panel, as
shown in Fig. 31.
CAUTION
Fig. 31
07-156 CM-CLM1972-3172 6/6/07 9:35 AM Page 24

Other manuals for Sanyo CLM1972

Related product manuals