T e mp . S e t t i n g
K e y L o c k
2
T e mp e r a t u r e - 8 0
o
C ( - 5 0
o
C - - 9 0
o
C )
3
H i g h A l a r m + 1 0
o
C ( + 5
o
C - + 2 0
o
C )
4
L o w A l a r m - 1 0
o
C ( - 5
o
C - - 2 0
o
C )
5
A l a r m D e l a y 15min (0 - 15mi n )
R i n g B a c k 3 0 mi n ( 0 . O F F 1 - 9 9 m i n )
6
K e y L o c k 0 P a s s w o r d
M E N U
K
C a n c e l
0
1
0
2
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
1
T emp . S e t t i ng
2
T e m p e r a t u r e - 8 0
o
C (-50
o
C - - 9 0
o
C )
3
H i g h A l a r m +10
o
C ( + 5
o
C - + 2 0
o
C )
4
L ow A l a r m -10
o
C (-5
o
C - -2 0
o
C )
5
A l a r m D e l ay 15min (0 - 15min )
R i n g B a c k 30min (0.OFF 1-9 9 m i n )
6
K e y L o c k 0 ( 0 . U n l o c k 1 . L o c k )
0
1
0
2
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
1
Top Screen
2
Te
m
p - 8 0
o
C
3
Alarm
N
or m a l
4
S
tatus
Stan d - b y
5
D
oor
Clos e d
6
2 0 08/ 04/ 01 12: 00: 00
㧙㧤㧜
M E N U
S e t
Lo g
To o l s
Basic Screen
2MENU/Set Temperature/alarm setting
Temperature setting range: -50㷄䌾-90 Factory default: -80㷄䋩
High temp. alarm setting range: Set temp.+5㷄䌾 +20 Factory default: +10㷄䋩
Low temp. alarm setting range: Set temp.-5㷄䌾 -20㷄䋨Facotry default: -10㷄䋩
”Alarm Delay” : Settable range of alarm delay time is 015 minutes. When it is set up in 0 minute, the buzze
r
sounds immediately with no delay. (Factory default: 15 min.)
䊶㵱Ring Back”: This is the time between the acknowledgement of alarm buzzer and return of the alarm buzzer.
The settable range is 199 minutes. Alarm buzzer is not back again when it is set in 0.Factory default: 30min. )
䊶㵱Key Lock”: When “Lock” is chosen, the set point cannot be changed. Input of the password is necessary to
release. (Factory default: 0000)
Temperature setting
, high/low temp. alarm temperature, alarm delay time, Ring Back time cannot be changed
when Key Lock is on.
Note
Alarm buzzer sounds after 15 minutes delay (Factory default) once the unit is in an alarm condition.
Temperature Setting Screen
Release of Key Lock
It is necessary to input the password to release key lock. (Factory default: 0000)
If you forget the password;
In “Select Tools Svc” screen, select “Calibration 2” and “Function”.
Input “101” to indicate a current password forcibly.