T o p S c r e e n
2
T e
p - 8 0
o
C C o n t r o l : S T D
3
A l a r m
N
or mal
4
S
t a t u s
St and- by
5
D
o o r
Closed
6
2 0 0 8 / 1 2 / 0 1 1 2 : 0 0 : 0 0
㧙㧤㧜
M ENU
Se t
L
o g
Tool s
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
1
( - 2 5
C ) 2 0 0 8 / 0 3 / 3 1 C h a mb e r T e m p
3
4
5
6
0 (
- 1 0 0
C ) 1 2 24
M ENU
P C 1 D
P C A l l
C l e a r
Cancel
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
1
Progress
3
Send log data to P C .
4
5
Log Dat e 2008/ 03 / 3 1
6
Fi ni shed.
MENU
St ar t
Ca nc e l
4. MENU/Log
Basic Screen
䊶All accumulated records are indicated with a graph point.
䊶1 page provides 24-hours of data
䊶Temperature range is changed with and .
Temperature: 50䌾-25㷄 for page 1, -25䌾-100㷄 for page 2
䊶It is moved with and to date.
䋨 : Older date : Newer date䋩
䊶Data interval: 2䌾30 minutes 䋨Factory default: 15min.䋩
With 15 min. interval, recording for about 5weeks is available
䊶Display resolution: 1㷄/point, 10min./point
䊶㩷 When log data memory is full, the oldest data is written
over.
䊶Press Clear button to display confirmation screen.
Select MENU/OK to eliminate all log data.
䊶Press PC 1D button to display confirmation screen.
Log data for one day (displayed date) is transferred.
䊶Press PC ALL button to display confirmation screen.
All memory log data will be transferred.
<Log data>
Chamber temperature, compressor A/B protection
temperature, ambient temperature, door open/close (1: Open,
0:Close), cooling circuit abnormality, fan motor abnormality
Data transmission
PC setting for receiving log data 䋨for Windows 2000, XP䋩
1. Start a program 㵨 accessories 㵨 communication 㵨 hyper-terminal from the starting button.
䋨The registration of the starting menu is to start in the following method, C:¥Program Files¥Windows
NT¥hypertrm.exe䋩
2. Set up the following through the hyper-terminal screen.
New connection Name㩷䋨Ex.䋩Sanyo
Set up of connection Connection port㩷 COM1
Properties of COM1㩷 Set up of port
Bit/Sec.9600, Data bit: 8, Parity: No, Stop bit: 1, Flow control: Xon/Xoff
䋨When a log transmitting screen is opened, terms of communication on the MDF side are set on the
above condition automatically.䋩
3.
The communication cable for the interface board MTR-480 option and 9 pin Dsub cross type for RS232C is
necessary for the data transmission to the PC.
Operation of hyper-teminal on PC side
Specify transmission, text capture and file
name, press start button.
䊶 Select MENU/Start to transmit the data to PC.
䊶 The transmission is complete when the message
“Finished” is indicated.
Graph display
The communication cable for the interface board
MTR-480 option and 9 pin Dsub cross type fo
RS232C is necessary for the data transmission to
PC.