PDG-DXT10L
- 46-
5-3Calibrate YUV
Step1
In Service Mode Select ADC Calibration
Item and press “Select” key , and then you
will see the picture as follow。
Step2
Select “Calibration”. In this menu input
pattern with 75﹪SMPTE pattern for
calibrate YUV Source and notice that the
input source must be 480p format 。
After input ready press “Select” key to
proceed, or if you won’t do calibration just
press “Menu” key to leave。
Input Pattern