- 65 -
Service Adjustment
Group/
Item
Item Name Function Initial Range Note
11 OnStart Cooling Start Threshold
With Onstart on. At the time of
Power on after Cooling imperfect.
Cooling The temperature set point
for existence judgement
38 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read
only)
- 0-255
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage
Down ( V×10)
0 0-0
2 Fan1 Speed Gain
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
10 0-255
3 Fan2 Speed Gain 10 0-255
4 Fan3 Speed Gain 10 0-255
5 Not used -
Group 257 Fan Dimmer Setting
0 Dimmer Average Check Period
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:60sec, 3: 90sec
...10:300 sec)
1 0-10
1 Dimmer Average Dimmer Avarage Value (Read only) -
2 Last Voltage Dierence Read only (Unit : o.1V) -
3 Voltate Dierence Goal Read only (Unit : o.1V)
Group 258 Fan IC Temp for Netowrk model
0 Standby Cooling Check Cycle
Temp B Check Cycle (Standby
mode) Unit : minute
3 0-100
1
Standby Cooling Start
Threshold
Temp B start threshold (Standby
mode) Unit : minute
44 0-100
2 Standby Cooling Enable 0 : Disable 1 : Enable 1 0-1
Group 260 Auto Calibration (Commn)
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when
changiing the Value (PC White 100%)
1 Loop Count
Maximum Execution Times (OFFSET-
>GAIN)
10 1 - 30
2 Auto Status
Result of Auto-Calibration (Last
Memory)
0 0 / 1 / 9 0: OK, 1: Adjusting,9: Error * ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START
Black Level Acquiring Area H-Start
Position
975 0 - 1000
1 OFFSET AREA V START
Black Level Acquiring Area V-Start
Position
500 0 - 1000
2 GAIN AREA H START
White Level Acquiring Area H-Start
Position
25 0 - 1000
3 GAIN AREA V START
White Level Acquiring Area V-Start
Position
500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT
Black/White Level Acquiring Area
Height
9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1 - 255
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0 - 1000
6 Image Area H Width Image Level Acquiring Area 8 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 217 0 - 255
11 Gain Tolerance Torelance of Level Adj. 1 0 - 255
12 Delta Gain Deviation Width of Gain Value 9 0 - 255
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
Y - Oset Acquiring Area H-Start
Position
925 0 - 1000
1 Y-OFFSET AREA V START
Y - Oset Acquiring Area V-Start
Position
500 0 - 1000
2 CB - OFFSET AREA H START
CB - Oset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
3 CB - OFFSET AREA V START
CB - Oset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value