Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
20 0-100
16 Temp B Warning Offset (Temp) 20 0-100
17 Temp C Warning Offset (Temp) 20 0-100
18 Temp B-A Warning Offset (Temp) 0 0-100
19 Temp C-A Warning Offset (Temp) 0 0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
5 0-5
21 Temp B Warning Offset (Time) 5 0-5
22 Temp C Warning Offset (Time) 5 0-5
23 Temp B-A Warning Offset (Time) 1 0-5
24 Temp C-A Warning Offset (Time) 1 0-5
Group 254 Fan Control Range Setting (Temp./Voltage) Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 n/a 9999
1 n/a 9999
2 n/a 9999
3 n/a 9999
4 n/a 9999
5 n/a 9999
6 n/a 9999
7 n/a 9999
8 n/a 9999
9 n/a 9999
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p at
Normal
46 46 99 99 20-100
11 Normal Fan Control Max Temp 49 49 99 99 20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
77 77 135 135 0-255
13 Normal Fan1 Max 135 135 135 135 0-255
14 Normal Fan2 Min 84 84 130 130 0-255
15 Normal Fan2 Max 130 130 130 130 0-255
16 Normal Fan3 Min 9999 -
17 Normal Fan3 Max 9999 -
18 Normal Fan4 Min 9999 -
19 Normal Fan4 Max 9999 -
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p at Eco
47 47 99 99 20-100
21 Eco Fan Control Max Temp 50 50 99 99 20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
55 55 120 120 0-255
23 Eco Fan1 Max 115 115 120 120 0-255
24 Eco Fan2 Min 65 65 91 91 0-255
25 Eco Fan2 Max 86 86 91 91 0-255
26 Eco Fan3 Min 9999 0-255
27 Eco Fan3 Max 9999 0-255
28 Eco Fan4 Min 9999 -
29 Eco Fan4 Max 9999 -
Group 255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70 0-255
1 Fan2 Initial Volt 70 0-255
2 FNot used 9999 0-255
3 Not used 9999 -
4 Fan1 Cooling Speed Fan Voltage at Power Off (0.1V) 130 0-255
5 Fan2 Cooling Speed 130 0-255
6 Not used 9999 0-255
7 Not used 9999 -
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
9 Cooling Time L2
Cooling Time stting at Fan Mode L2 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
4 1-15
10 Temp Error Cooling Time Cooling Time setting at Temp Erro (x 30 sec) 3 1-15
11 OnStart Cooling Start Threshold 38 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (0.1V)(Read only) - 0-255
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage Down (
10)
0 30-90