Loading...
11
2-2-2. Outdoor Unit
Outdoor Unit SAPC161GA
Compressor
Type Rotary (Hermetic)
Compressor model C-R140H5W 80610045-S
Nominal output W 1,400
Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 500
Coil resistance (Ambient temp. 25°C) C–R : 1.560
C–S : 3.610
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA99150-9201 TS-120N
Operating temp. Open °C 145±5 120±5
Close °C 69±11 95±11
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 23.5A
Run capacitor µF 35.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø420
Fan motor model ... Q'ty KFG6S-51A5P-S ... 1
No. of poles ... rpm (High) 6 ... 870
Nominal output W 50
Coil resistance (Ambient temp. 20°C) WHT-BRN : 67.09
WHT-YEL : 68.12
YEL-PNK : 15.66
Safety devices Type Internal protector
Operating temp. Open °C 130±8
Close °C Automatic reclosing
Run capacitor µF 4.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area
m
2
0.506
External Finish Acrylic baked-on enamel finish