5
Indoor Unit SAPK181GJA SAPK181MBA
Outdoor Unit SAPC181JA SAPC181BA
Power Source
220V Single phase 60Hz
Voltage rating 220 V
Performance Cooling
Capacity kW 5.15
BTU/h 17,600
Air circulation (High)
m
3
/h
760
Moisture removal (High) Liters/h 2.7
Electrical Rating Cooling
Available voltage range V 198 ~ 242
Running amperes A 7.8
Power input W 1,700
Power factor % 99
C.O.P. W/W 3.0
Compressor locked rotor amperes A 41
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer 1-hour OFF / 12-hours ON or OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto(Hi, Lo)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R22 / 1,150
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor : Hi dB-A 51
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 12.7(1/2)
Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275
Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 369
Weight Net kg 12.0 47.5
Shipping kg 15.0 52.0
Shipping volume
m
3
0.11 0.25
DATA SUBJECT TO CHANGE WITHOUT NOTICE.