2-2-2. Outdoor Unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Type Rotary (Hermetic)
Compressor model ... Number C–1R71H5U ... 2 / 80688745S ... 2
Nominal output W 700
Compressor oil ... Amount cc 4GSD–T or SAY-56T ... 320
2
Coil resistance (Ambient temp. 25°C) C – R : 4.57
C – S : 6.90
Type External protector (OLR 1, 3) External protector (OLR 2, 4)
Safety
Overload relay ... Number MRA987829201 ... 2 CS7C115 ... 2
devices Operating temp. Open °C 130 ± 5 115 ± 3
Close °C 69 ± 11 95 ± 5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 13.5A
Run capacitor ... Number µF 20.0 ... 2
VAC 400 ... 2
Type Propeller
Number ... Dia. mm 1 ... ø420
Fan motor model ... Number KFG651C5PS ... 1
No. of poles ... rpm (230 V) 6 ... 870
Nominal output W 50
Coil resistance (Ambient temp. 20°C) WHT – BRN : 67.1
WHT – YEL : 83.8
Safety
Type Thermal protector
devices Operating temp. Open °C 130 ± 8
Close Automatic reclosing
Run capacitor µF 4.0
VAC 440
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area m
2
0.506
External Finish Acrylic baked-on enamel finish
Heat
Exch. Coil
Compressor
Fan & Fan Motor
Outdoor Unit SAPCM1621GA
6