7. ELECTRICAL DATA
7-1. Electrical Characteristics
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at
230V Single phase 50Hz
Rating Conditions Running Amps. A 0.36 0.49 5.65 6.5
Power Input kW 0.074 0.112 1.264 1.45
Full Load Conditions Running Amps. A 0.36 0.49 6.85 7.7
Power Input kW 0.074 0.112 1.534 1.72
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit SAPK91GA (
2)
Outdoor Unit SAPCM1621GA
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at
230V Single phase 50Hz
Rating Conditions Running Amps. A 0.18 0.49 2.83 3.5
Power Input kW 0.037 0.112 0.631 0.78
Full Load Conditions Running Amps. A 0.18 0.49 3.63 4.3
Power Input kW 0.037 0.112 0.811 0.96
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit SAPK91GJA (
1)
Outdoor Unit SAPCM1621GA