2-2. Major Component Specifications
2-2-1. Indoor Unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. POW–K91GJA
Controls Microprocessor
Control circuit fuse 250 V – 3.15 A
Remote Control Unit RCS–2S2E
Type Cross–flow
Number ... Dia. and length mm 1 ... ø95 / L578
Fan motor model ... Number IBH-884-020 ... 1
No. of poles ...50/60Hz rpm (High) 2 ... 1,280/1,280
Nominal output W 20
Coil resistance (Ambient temp. 20°C) WHT – BRN : 201
WHT – VLT : 261
Safety Type Thermal fuse
devices Operating temp. Open °C 130
Close
Run capacitor µF 1.5
VAC 440
Type Stepping motor
Model MP24GA3
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) A pair of each terminal: 380 ± 7%
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area m
2
0.110
Heat
Exch. Coil
Flap Motor Fan & Fan Motor
Controller
PCB