4
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
No. of indoor units. 1-unit 2-units
Power Source 220V Single phase 60 Hz
Cooling
Capacity kW 2.60 5.20
BTU/h 8,900 17,700
Air circulation (High) m
3
/h 430 430
2
Moisture removal (High) Liters/h 0.85 0.85
2
Voltage rating V 220
Available voltage range V 198 to 242
Running amperes A 4.6 8.5
Power input W 960 1,840
Power factor % 95 98
C.O.P. W/W 2.7 2.8
Compressor locked rotor amperes A 24 48
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer 1-hour OFF / 12-hour ON or OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, AntiMold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R22 / 1,320 (660
2)
Refrigerant control Capillary tube
Operation sound Indoor – Hi / Me / Lo dB-A 39 / 37 / 33
Outdoor – Hi dB-A 53
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant tube
Narrow tube mm (in.) 6.35 (1/4)
diameter
Wide tube mm (in.) 9.52 (3/8)
Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Indoor Unit Outdoor Unit
Unit dimensions Height mm 250 630
Width mm 790 810
Depth mm 174 275
Package dimensions Height mm 242 704
Width mm 850 953
Depth mm 312 369
Weight Net kg 7.0 48.0
Shipping kg 10.0 52.5
Shipping volume m
3
0.06 0.25
Dimensions & Weight Features Electrical Rating Performance
Indoor Unit SAPK91GJA
Outdoor Unit SAPCM1821JA