33
B.Circuit breaker trips in several minutes after turning the air conditioner on.
There is a possibility of short circuit.
Replace with suitable
one (larger capacity).
NO
Check capacity of circuit breaker.
Capacity of circuit breaker is
suitable.
Measure resistance of outdoor fan
motor winding.
Measure resistance of compressor
motor winding.