7
Outdoor Unit SAPC122AH
Controller PCB
Compressor
Type Rotary (Hermetic)
Compressor model C-R112H5X 80616745-S
Nominal output W 1,100
Compressor oil ... Amount cc 4GSD-T or SAY-56T ... 550
Coil resistance (Ambient temp. 25°C) C–R : 1.962
C–S : 5.38
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA98596-9201 CS-7C115
Operating temp. Open °C 145±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 21A
Run capacitor µF 25.0
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø370
Fan motor model ... Q'ty UE6S-21AC5P-S ... 1
No. of poles ... rpm (230 V, High) 6 ... 750
Nominal output W 20
Coil resistance (Ambient temp. 20°C) BRN-WHT : 341.2
WHT-YEL : 212.7
YEL-PNK : 190.0
Safety devices Type Thermal fuse
Operating temp. Open °C 145 ± 2
Close °C
Run capacitor µF 1.5
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.2
Face area
m
2
0.329
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.