2-3. Other Component Specifications
8
This power relay is provided to protect the outdoor fan to operate in Low fan speed during heating mode.
In heating operation, the outdoor fan should always run in High fan speed to prevent the unit from freezing.
PTC Thermistor (TH) ZPROYCE101A500
Rating 400V, 115A
4-way Valve (20S) LB81012 (Coil), VK1100B (Valve)
Coil rating AC 220/240V, 50/60Hz, 6W
Coil resistance Ω (at 20°C) 3,030 ± 7%
Power Relay (for outdoor fan motor) HH62S AC220/240V
Coil rating AC 220/240V
Contact rating AC 250V, 10A
Thermostat (Fan Speed Control 23S) MQT5S
Switching temp. °C
high ➞ LOW 28.5°C ± 1.5
low ➞ HIGH 31.5°C ± 2
Contact rating AC 220V, 3A
4-way Valve (20S) LB81012 (Coil), VK1100B (Valve)
Coil rating AC 220/240V, 50/60Hz, 6W
Coil resistance Ω (at 20°C) 3,030 ± 7%
Thermistor (Room sensor) DTN-TKS128B
Resistance kΩ 25°C 5.0 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance kΩ 0°C 15.0 ± 2%
Transformer (TR) ATR-I55
Rating Primary AC 230V, 50/60Hz
Secondary 13.7V, 0.4A
Capacity 5.48VA
Coil resistance Ω (at 25°C) Primary (WHT – WHT): 307 ± 10%
Secondary (BRN – BRN): 1.8 ± 10%
Thermal cut-off temp. 150°C
Indoor Unit SAP–K92AH
SAP–K122AH