9-3. Some part of air conditioner does not operate.
9-3-1. Only indoor fan does not run.
9-3-2. Only flap motor does not run.
9-3-3. Function of outdoor fan speed control does not work properly. (For C122 model)
Refer to "8-9 Outdoor Fan Speed Control ".
9-3-4. Only outdoor fan does not run.
Fan cannot
be turned.
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor winding
burnout or foreign
matter in bearings.
Remove foreign
matter or repair.
Repair or replace.
OK
Measure resistance of indoor fan
motor winding.
Check fan motor capacitor.
OK
Measure resistance of indoor fan
motor winding.
Check fan motor capacitor.
Check connectors to indoor PCB Ass´y.