EasyManua.ls Logo

Sanyo SAP – K92AH - 7-3. Recommended Wire Length and Diameter

Sanyo SAP – K92AH
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Regulations on wiring diameter differ from locality to
locality. For field wiring requirements, please refer to
your local electrical codes. Carefully observe these
regulations when carrying out the installation.
Table 2 lists recommended wire lengths and cross
section area for power supply systems.
Refer to the WIRING SYSTEM DIAGRAM for the
meaning of "A" and "B" in Table 2.
NOTE
Be sure to comply with
local codes on running the
wire from the indoor unit to
the outdoor unit (size of
wire and wiring method,
etc.).
Each wire must be firmly
connected.
No wire should be allowed
to touch refrigerant tubing,
the compressor, or any
moving part.
To avoid the risk of electric
shock, each air conditioner
unit must be grounded.
Be sure to connect the
power supply line to the
indoor unit as shown in the
wiring diagram.
The outdoor unit draws its
power from the indoor unit.
WARNING
WARNING
CAUTION
WIRING SYSTEM DIAGRAM
OUTDOOR UNITINDOOR UNIT
Terminal Terminal
Grounding Line
1
4
6
2
1
4
2
5
6
7
(B)
(A)
Grounding Line
Power supply:
1-phase,50 Hz,
220-240 VAC
5
7-3. Recommended Wire Length and Diameter
Table 2
(A) + (B)
(A) Power Supply Wiring Length (m)
(B) Power Line (m)
Fuse or
Circuit Breaker
Capacity
2 3.5
C92 33 51
10A
C122 27 41
Model
Cross Sectional
Area (mm
2
)

Table of Contents

Related product manuals