I - 124
SM830052
ECO MULTI SYSTEM Unit Specifications
1
Indoor unit (B)
MODEL No. SPW-FM123GH56
Source 220 - 230 - 240 V / 1 phase / 50Hz
Controller P.C.B. Ass’y CR-X253GH (Microprocessor)
Fan (Number…diameter) mm Centrifugal (1 … ø 153)
Fan motor
Model…Nominal output W KFT4Q-21B3P … 30 W
Source 220 - 230 - 240 V / 1 phase / 50 Hz
No. of pole…r.p.m. (230 V, High) rpm. 4 … 1,102
Coil resistance BRN WHT : 217.7 ORG YEL : 37.88
(Ambient temperature 20°C) WHT VLT : 37.33 YEL PNK : 21.82
VLT ORG : 22.48
Safety device
Operating temperature Open °C 148
+ 0
°C
Close °C—
Run capacitor VAC, µF 440 V, 2.0 µF
Electronic refrigerating control valve
Solenoid control model DKV-MOZS550E0
Coil resistance (at 20°C) ORG GRY : 46 , YEL GRY : 46
RED GRY : 46 , BLK GRY : 46
Solenoid control valve model IKV-24D12
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows…fin pitch mm 3 … 2.0
Face area m
2
0.102