III - 37
3
SM830052
Service Procedures
TH1, 2, 3
CM
CH
TH1 (WHT) (Discharge gas)
4-Way Valve (20S)
(except for SPW-C483GY8)
63PH
52C
0826_C_S
Save Valve (SAVE)
Low-pressure valve (LPV)
High-pressure valve (HPV)
2. Sensor and Solenoid Layout Diagram
2-1. Outdoor unit
7 SPW-C483GYH8, SPW-C483GY8
7 SPW-C703GYH8, SPW-C903GYH8
SPW-C703GY8 , SPW-C903GY8
0827_C_S
TH3 (BLK)
TH2 (YEL)
0849_C_I
1
2
1
2
1
2
WHT
WHT
BLK
BLK
BLK
BLK
TH1 (PC discharge)
TH2 (Outdoor coil)
TH3 (Coil liguid Side)
2P (WHT)
DISH
PC
2P (YEL)
EXC
2P (BLK)
EXL
0850_C_I
High-pressure valve (HPV)
Low-pressure valve (LPV)
Save valve (SAVE)
4-way valve (20S), (except for
SPW-C703GY8, SPW-C903GY8)
Liquid line valve (LLV)
0851_C_I
Heat exchange coil (TH3)
Heat exchange liquid
(TH4)
AC discharge (TH2)
PC discharge (TH1)
Compressor
Compressor
0852_C_I
1
2
1
2
1
2
1
2
WHT
WHT
WHT
WHT
BLK
BLK
BLK
BLK
TH1 (PC discharge)
TH2 (AC discharge)
TH3 (heat exchange coil)
TH4 (heat exchange liquid)
CN5
(WHT)
CN6
(GRN)
CN4
(YEL)
CN3
(BLK)

Table of Contents