GND
(+)
(–)
RED
A
B
✱
✱
WHITE
(GRAY/B
(BLA
(GN
(GN
(BL
(GN
Connections 1
9
Monitor Connection
• Using different cables from
those specified here may
attenuate the video and/or sync
signals and interfere with
correct transmission.
• RG-59U coaxial cables can be
used when distance between
devices is short, but not in duct
or aerial routing.
Cable type Length
RG-59U (3C-2V) 250 m (273 yds) max.
RG-6U (5C-2V) 500 m (547 yds) max.
RG-11U (7C-2V) 600 m (656 yds) max.
Note:
All connection cables should be 24 AWG or
higher with a maximum length of no more than
600 m (656 yds).
Coaxial cable
b With AC 24 V
Power Supply Connection
b With DC 12 V
Check that +/- polarity is correct.
✱ For the connections, use AWG (20, 21, 22)
cables.
1 Push and hold the lever a, and
then insert the cable into the
terminal hole
B.
2 Release the lever
A.
BNC type
Digital video recorder etc.
Shielded LAN cable
(CAT5 or higher, straight type)
See “Connection when Using PoE
Power Supply” or “Connection when
Not Using PoE Power Supply”.
L5CE2_CD2_XE(INSTALLATION).book 9 ページ 2008年4月16日 水曜日 午後3時18分