2-6-6.
MODE
DETECTION
SWITCH
POSITIONING
(See
Fig.
2-6-6.)
Mode
switch
positioning
is
necessary
when
the
mode
detec-
tion
switch
is
removed
and
replaced.
(1)
Turn
the
pulley
completely
clockwise,
and
then
return
it
one
turn
counterclockwise.
(2)
Check
to
be
sure
that
the
triangle
mark
on
the
mode
detection
switch
and
the
triangle
mark
on
the
slide
are
aligned.
(3)
If
they
are
not
aligned,
loosen
the
two
screws
(a),
move
so
that
the
triangle
mark
of
the
mode
detection
switch
is
aligned,
and
then
tighten
the
screws
(a).
(Bottom
View)
AN
Triangle
mark
—29—