EasyManua.ls Logo

Sartorius Master Pro LA2200S User Manual

Sartorius Master Pro LA2200S
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
W--5032-e03013
Q
U
A
L
I
T
Y
S
Y
S
T
E
M
C
E
R
T
I
F
I
E
D
Q
U
A
L
I
T
Y
S
Y
S
T
E
M
R
e
g
.
N
o
.
1
9
4
4
0
-
0
2
C
E
R
T
I
F
I
E
D
DIN EN ISO 9001
Sartorius AG, Weighing Technology
Sartorius AG, Weighing Technology
Sartorius Master
pro
Serie
Electronic Precision Balances
Service Manual
for LP / LA Models

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sartorius Master Pro LA2200S and is the answer not in the manual?

Sartorius Master Pro LA2200S Specifications

General IconGeneral
BrandSartorius
ModelMaster Pro LA2200S
CategoryScales
LanguageEnglish

Summary

Operating the Balance

Key Functions

Description of the functions of each key on the balance.

SETUP Program

Steps to turn on the balance and access the SETUP program.

INPUT Mode

Procedure for entering data into the balance.

Overview of the User / Service SETUP Program

Flowchart illustrating user and service SETUP program navigation.

Service Switches

Activating the BPI Mode / Deactivating the Write Protection

Steps to activate BPI mode for calibration or PCB replacement.

Activating the Service Mode

How to enable expanded calibration/adjustment functions.

Calibration/Adjustment in the Service Mode

List of available adjustment options within service mode.

External Linearization

Methods for performing external linearization.

Manual Input of the Linearization Weights

Steps to manually input specific linearization weights.

Performing External Linearization

Detailed procedure for the external linearization routine.

Internal Span Adjustment

Procedure for internal span adjustment using the built-in weight.

External Span Adjustment

Overview of external span adjustment methods.

External Span Adjustment with Manual Input of Weight Values

Inputting specific weights for span adjustment.

External Span Adjustment with Stored Weight

Performing span adjustment using pre-defined stored weights.

Overwriting the Internal Calibration Weight

Procedure to overwrite the internal calibration weight.

Calibration with a User-defined Weight

Steps to define and use custom calibration weights.

reproTEST

Test for reproducibility of the built-in calibration weight.

Servicing the Weighing Cell

Removing the Display and Control Unit from the Weighing Cell

Steps to disconnect and remove the display/control unit.

Opening the Weighing Cell (Small Single-Casting Block System, Brass System)

Procedure for opening specific types of weighing cells.

Opening the Weighing Cell (Large Single-Casting Block System)

Procedure for opening large single-casting block weighing cells.

Accessing the Main PCB

Steps to access and locate the main PCB.

Opening the Display and Control Unit

Detailed steps for opening the display and control unit.

Replacing the Built-in Calibration Weight

Procedure for replacing the balance's built-in calibration weight.

Calibration/Adjustment

Calibration/Adjustment Sequence

Factors to check and adjust during calibration.

Adjusting the Preload

Detailed steps for adjusting the preload.

Adjusting the Off-center Load

Steps to adjust the off-center load for different systems.

Span Accuracy

How to check the span accuracy of the balance.

Linearity

Overview of linearity checking procedures.

Checking the Linearity on Balances with Less Than 1,000,000 Digits

Linearity check for balances with lower resolution.

Repairing the Balance

Replacing the PCB in the Display and Control Unit

Steps to replace the PCB in the display and control unit.

Replacing the Balance PCB

Steps to replace the main balance PCB.

Masterpro Balances with the Small Single-Casting Block System or Brass System

PCB replacement procedures for specific balance systems.

Masterpro Balances with the Large Single-Casting Block System

PCB replacement for large single-casting block systems.

Related product manuals