45
Step
(Shown below,
near the gear
icon)
Display
on
display
Selectable values
(in brackets is the factory
default value)
Description
9
FA
NO / NC (NC)
Output valve mode:
NO NO (normally open), Open valve
NC NC (normally closed) Closed valve
10
P52
4 / 6 (4)
Number of heating program switches.
Here you can select the number of your daily heating
program switches. You can have 4 or 6 daily switches at
different hours. The default hours for 4 daily switches are
6:00, 8:00, 18:00, 22:00; For 6 daily switches are: 6:00,
8:00, 12:00; 14:00; 18:00, 22:00. All of the above values are
just the default set. You can change them regarding your
desires of heating program schedule.
All of the advanced settings can be reset to factory default values by holding the middle menu button (button
description 3) for 3 seconds, while in editing mode. Screen will display dEF and all settings will be reset.