SATEL CA-5 5
finishing the function and exiting the user menu, after confirming the entered data.
6 short beeps – arming, with some zones bypassed.
1 long beep – refusal to arm (some zones are violated) or function unavailable.
2 long beeps – an unknown code, unavailable function, or exiting the function without
confirmation of the data entered (e.g. after using
key).
3 long beeps – unavailable function.
Events signaled by sounds
1 short beep every 3 seconds – to signal:
service mode;
new trouble.
5 short beeps – zone violation (CHIME).
2 short beeps every seconds – countdown of entry delay.
1 long beep every 3 seconds – exit delay countdown.
Continuous beep – alarm.
Long beep every second – fire alarm.
Notes:
Only installer selected events are signaled.
Alarms will be signaled as long as programmed by the installer.
2. Codes and users
An individual code is assigned to every control panel user. The code makes it possible to use
functions available in the keypad and to operate the control panel using the keypad. By
default, the following codes are preprogrammed in the control panel:
master (administrator) code: 1234
service code: 12345
Using the master code you can program 5 codes for other users. The installer defines the
rights (authority level) for codes 4 and 5.
The service code enables access to the service functions, but does not allow everyday
operation of the control panel (using this code you will not be able to arm or disarm the
system).
3. Arming
Prior to arming, make sure that there are no violated zones (e.g. open windows or doors),
which may prevent the system from arming (if the system has been so configured by the
installer).
After arming, the exit delay countdown may be running, which allows you to leave the
premises without triggering alarm (the zones will be armed only when the exit delay
countdown is finished).
The installer may program the control panel so that the users can stay inside the premises
after the system is armed. If, during the exit delay countdown, the control panel will not
register leaving the premises (the zone monitoring the exit route will not be violated), the
selected zones will be bypassed.