1471
Firmware Version 1.00
Alarm Control Panel
USER
MANUAL
SATEL sp. z o.o.
ul. Budowlanych 66
80-298 Gdańsk
POLAND
tel. +48 58 320 94 00
www.satel.eu
perfecta_u_en 02/17

Table of Contents

Other manuals for Satel PERFECTA

Question and Answer IconNeed help?

Do you have a question about the Satel PERFECTA and is the answer not in the manual?

Summary

WARNING

Factory Default Codes

Lists the default service and user codes for the alarm system.

Symbols Used in Manual

Explains the meaning of informational and warning symbols used in the manual.

1. Introduction

SATEL Company Overview

Provides company background, product information, and website details.

2. Technical Reliability of the Alarm System

System Safeguards and Diagnostics

Details the system's built-in safeguards and diagnostic functions for performance testing.

3. Alarm System Operating Costs

Cost Factors and Management

Explains how system reporting and programming affect operating costs.

4. Glossary

Alarm System Terminology

Defines key terms and concepts related to the alarm system.

5. EN 50131 Standard Compliance

Grade 2 Requirements Overview

Outlines specific user code and feature requirements for EN 50131 Grade 2 compliance.

6. Keypads

Keypad Description

Details the physical layout and components of the PERFECTA keypads.

LED Indicators

Explains the function of LEDs on the keypad for indicating partition and system status.

Keypad Display Functionality

Display Information and Symbols

Describes the information displayed on the keypad and zone status symbols.

Keypad Keys and Sound Signaling

Keypad Keys Overview

Details the specific functions of each key on the keypad for system operation.

Sound Signaling Types

Explains the different types of beeps and their meanings for user feedback.

Codes and Event Signaling

System Access Codes

Explains the use of user codes for system access and operation.

Event Signaling Beeps

Details the various beep patterns for events like alarms, troubles, and system states.

Arming Procedures

Arming Without Partition Selection

Steps to arm the system without specifying a particular partition.

Arming Selected Partitions

Process for arming specific partitions of the alarm system.

Quick Arming Method

Method for arming the system quickly without code entry.

Arming Process and Failures

Terminating Exit Delay Countdown

How to shorten the exit delay countdown.

System Not Ready and Forced Arming

Explains reasons for arming failure and how to force arming.

Disarming and Alarm Clearing

Disarming Without Partition Selection

Steps to disarm the system and clear alarms across all accessible partitions.

Triggering Alarms from Keypad

How to manually trigger panic, fire, or medical alarms from the keypad.

User Menu Navigation

How to navigate and use the user menu for system functions.

User Menu Navigation and Data Editing

Navigating Through Menus

Methods for navigating submenus and selecting functions using keys.

Data Editing Methods

How to edit data such as names, codes, and settings within the user menu.

User Functions List

Key Sequences for Functions

Lists key sequences to access various user functions like changing codes or managing users.

User Management Functions

Details on adding, editing, and removing users and their settings.

User and System Management

Changing User Codes

Instructions for changing the user's access code.

Outputs Reset Function

How to reset or activate specific outputs connected to the alarm system.

User Management Details

Adding a New User

Step-by-step guide to adding a new user to the system with specific rights.

User Schedule Settings

Explains installer-defined schedules that determine user rights and keyfob operation.

User and Keyfob Management

Editing and Removing Users

Procedures for modifying existing user data and deleting users.

Adding and Configuring Keyfobs

How to add, configure, and remove keyfobs for system operation.

Zone Bypassing and Outputs Reset

Outputs Reset Functionality

How to reset or activate specific outputs connected to the alarm system.

Zone Inhibiting Procedure

How to temporarily disable zones from triggering alarms.

Zone Isolation and Event Log

Zone Isolation Procedure

How to isolate zones, keeping them bypassed until explicitly unbypassed.

Viewing the Event Log

How to access and interpret the system's event log for troubleshooting.

Setting the Clock

Instructions for setting the system's date and time.

System State and Output Control

Checking Troubles and System State

How to check for system troubles, bypassed zones, and partition status.

Output Control via Keypad

How to control connected devices (outputs) using the keypad.

System Tests

Zone and Detector Testing

How to perform tests on system zones and detectors.

Output and Siren Testing

Procedures for testing system outputs and sirens.

GSM;Radio Signal Check

How to check the signal strength of GSM and radio communication modules.

Transmission Tests and Device Information

Test Transmission Procedure

How to initiate a test transmission to monitoring stations.

ID and Firmware Version Checks

How to check panel ID, IMEI, and firmware versions of system devices.

SIM Card Management

Checking SIM Card Balance

How to check the credit balance of SIM cards installed in the panel.

Topping Up and Unblocking SIM Cards

Procedures for adding credit and unblocking SIM cards using PUK codes.

Service Access Rules

Defining Service Access Permissions

How to configure rules for installer/technician access to the system.

Remote Communication and Service

PERFECTA Soft Communication via GPRS

How to establish remote programming using the PERFECTA SOFT program.

Service Mode Operations

Accessing and using the service mode for system configuration.

Listening In and Keyfobs

Listening In Feature

How to use the listening-in feature if a microphone is connected.

Keyfob Operation

Using the MPT-350 keyfob to operate the alarm system.

SMS Control

SMS Command Structure

How to use SMS messages to control the alarm system with specific commands.

PERFECTA CONTROL Application

Mobile App Features

Overview of the PERFECTA CONTROL mobile application for remote system operation.

Siren Signals

Siren Sound;Flash Patterns

Explains the different sound and flash signals used by the siren to indicate system status.

Summary

WARNING

Factory Default Codes

Lists the default service and user codes for the alarm system.

Symbols Used in Manual

Explains the meaning of informational and warning symbols used in the manual.

1. Introduction

SATEL Company Overview

Provides company background, product information, and website details.

2. Technical Reliability of the Alarm System

System Safeguards and Diagnostics

Details the system's built-in safeguards and diagnostic functions for performance testing.

3. Alarm System Operating Costs

Cost Factors and Management

Explains how system reporting and programming affect operating costs.

4. Glossary

Alarm System Terminology

Defines key terms and concepts related to the alarm system.

5. EN 50131 Standard Compliance

Grade 2 Requirements Overview

Outlines specific user code and feature requirements for EN 50131 Grade 2 compliance.

6. Keypads

Keypad Description

Details the physical layout and components of the PERFECTA keypads.

LED Indicators

Explains the function of LEDs on the keypad for indicating partition and system status.

Keypad Display Functionality

Display Information and Symbols

Describes the information displayed on the keypad and zone status symbols.

Keypad Keys and Sound Signaling

Keypad Keys Overview

Details the specific functions of each key on the keypad for system operation.

Sound Signaling Types

Explains the different types of beeps and their meanings for user feedback.

Codes and Event Signaling

System Access Codes

Explains the use of user codes for system access and operation.

Event Signaling Beeps

Details the various beep patterns for events like alarms, troubles, and system states.

Arming Procedures

Arming Without Partition Selection

Steps to arm the system without specifying a particular partition.

Arming Selected Partitions

Process for arming specific partitions of the alarm system.

Quick Arming Method

Method for arming the system quickly without code entry.

Arming Process and Failures

Terminating Exit Delay Countdown

How to shorten the exit delay countdown.

System Not Ready and Forced Arming

Explains reasons for arming failure and how to force arming.

Disarming and Alarm Clearing

Disarming Without Partition Selection

Steps to disarm the system and clear alarms across all accessible partitions.

Triggering Alarms from Keypad

How to manually trigger panic, fire, or medical alarms from the keypad.

User Menu Navigation

How to navigate and use the user menu for system functions.

User Menu Navigation and Data Editing

Navigating Through Menus

Methods for navigating submenus and selecting functions using keys.

Data Editing Methods

How to edit data such as names, codes, and settings within the user menu.

User Functions List

Key Sequences for Functions

Lists key sequences to access various user functions like changing codes or managing users.

User Management Functions

Details on adding, editing, and removing users and their settings.

User and System Management

Changing User Codes

Instructions for changing the user's access code.

Outputs Reset Function

How to reset or activate specific outputs connected to the alarm system.

User Management Details

Adding a New User

Step-by-step guide to adding a new user to the system with specific rights.

User Schedule Settings

Explains installer-defined schedules that determine user rights and keyfob operation.

User and Keyfob Management

Editing and Removing Users

Procedures for modifying existing user data and deleting users.

Adding and Configuring Keyfobs

How to add, configure, and remove keyfobs for system operation.

Zone Bypassing and Outputs Reset

Outputs Reset Functionality

How to reset or activate specific outputs connected to the alarm system.

Zone Inhibiting Procedure

How to temporarily disable zones from triggering alarms.

Zone Isolation and Event Log

Zone Isolation Procedure

How to isolate zones, keeping them bypassed until explicitly unbypassed.

Viewing the Event Log

How to access and interpret the system's event log for troubleshooting.

Setting the Clock

Instructions for setting the system's date and time.

System State and Output Control

Checking Troubles and System State

How to check for system troubles, bypassed zones, and partition status.

Output Control via Keypad

How to control connected devices (outputs) using the keypad.

System Tests

Zone and Detector Testing

How to perform tests on system zones and detectors.

Output and Siren Testing

Procedures for testing system outputs and sirens.

GSM;Radio Signal Check

How to check the signal strength of GSM and radio communication modules.

Transmission Tests and Device Information

Test Transmission Procedure

How to initiate a test transmission to monitoring stations.

ID and Firmware Version Checks

How to check panel ID, IMEI, and firmware versions of system devices.

SIM Card Management

Checking SIM Card Balance

How to check the credit balance of SIM cards installed in the panel.

Topping Up and Unblocking SIM Cards

Procedures for adding credit and unblocking SIM cards using PUK codes.

Service Access Rules

Defining Service Access Permissions

How to configure rules for installer/technician access to the system.

Remote Communication and Service

PERFECTA Soft Communication via GPRS

How to establish remote programming using the PERFECTA SOFT program.

Service Mode Operations

Accessing and using the service mode for system configuration.

Listening In and Keyfobs

Listening In Feature

How to use the listening-in feature if a microphone is connected.

Keyfob Operation

Using the MPT-350 keyfob to operate the alarm system.

SMS Control

SMS Command Structure

How to use SMS messages to control the alarm system with specific commands.

PERFECTA CONTROL Application

Mobile App Features

Overview of the PERFECTA CONTROL mobile application for remote system operation.

Siren Signals

Siren Sound;Flash Patterns

Explains the different sound and flash signals used by the siren to indicate system status.

Satel PERFECTA Specifications

General IconGeneral
ModelPERFECTA
CategoryControl Panel
Outputs8
Users15
Partitions2
Tamper protectionYes
Operating Temperature-10°C to +55°C
CommunicationGSM
Power Supply12 V DC
Supported detectorsWired, wireless
Battery Backup7 Ah / 12 V
Humidity93%
Zones32

Related product manuals