12 PERFECTA SATEL
6.4.1 Disarming and alarm clearing without partition selection
Enter the code and then press . Disarming / alarm clearing will take place in the
partitions to which you have access.
6.4.2 Alarm clearing without disarming
If the partition is armed and you want to clear the alarm without disarming the partition, enter
the code and then press , or (it is of no consequence which key you will
press). In the partitions you have access to, the alarm will be cleared.
You cannot clear the warning alarm without disarming the system first.
6.4.3 Disarming and alarm clearing in selected partition
1. Select the partition which is to be disarmed and/or where alarm is to be cleared (press
one of the keys: - partition 1; - partition 2).
2. Press . Backlight of the keys will start blinking, which indicates that the code must be
entered.
3. Enter the code.
4. Press or .
5. Selected partition will be disarmed / alarm will be cleared.
6.5 Triggering the alarm from keypad
The installer can permit triggering alarms from the keypad. To trigger an alarm, do the
following:
fire alarm – press and hold down for about 3 seconds,
medical (auxiliary) alarm – press and hold down for about 3 seconds,
panic alarm – press and hold down for about 3 seconds. The installer defines whether
the loud panic alarm (setting off the loud alarm signal) or the silent panic alarm (without the
loud signal) will be triggered.
6.6 Turning the CHIME on /off
The CHIME is five short sounds by means of which the keypad will inform you e.g. that
a door / window is open, when the system is disarmed. The installer defines which zones of
the alarm system can trigger the CHIME and whether it can be turned on/off by the users.
Press and hold down
for about 3 seconds to turn on or off the CHIME signaling.
6.7 User menu
Enter the code and press to get access to the user menu. The functions you can run
will be displayed. The list of available functions depends on your rights, as well as on the
state and configuration of the system.
In order to quit the function and/or user menu, press . The keypad will quit the menu
automatically, if 2 minutes have elapsed since the last keypress.
6.7.1 Navigating through the menu and running functions
To navigate throughout the menu, you can use the arrow keys or number shortcuts. You can
also combine the two methods. The cursor shows the submenu you can enter / function
you can run.