6 SATEL Installer Manual
07 - keypad aux. alarm - the output starts on triggering the alarm by the user with the
ALARM AUX function. The output can remain active for a specified time (from 01
to 99 seconds or from 01 to 99 minutes) or until the alarm is cleared by the user.
During operation, it can every second change its state (pulsate).
08 - keypad tamper alarm - the output starts on detecting violation of the tamper contact or
a change of the keypad address and also after 3 wrong codes. The output can
remain active for a specified time (from 01 to 99 seconds or from 01 to 99 minutes)
or until the alarm is cleared by the user. During operation, it can every second
change its state (pulsate).
09 - day/night + counting - the output starts on detecting violation of disarmed DAY/NIGHT
zone or violations (triggering no alarm)
of COUNTING zones, which trigger no
alarm. Operation of the output can be restricted to a specified “list of zones”
(identically as for the 01 output type). Selection of any other zones than those
tested by this output type is irrelevant - they will give no violation signal. The
output can remain active for a specified time (from 01 to 99 seconds or from 01 to
99 minutes) or until the alarm is cleared by the user. During operation, it can every
second change its state (pulsate).
10 - duress alarm - the output starts on using an access code with authority level 4
(DURESS code) to disarm the system or to clear an alarm. This code is used to
trigger a special "disarm under duress" alarm. Operation of the output can be
restricted to alarms from particular partition. The output can remain active for
a specified time (from 01 to 99 seconds or from 01 to 99 minutes) or until the
alarm is cleared by the user. During operation, it can every second change its
state (pulsate).
11 - chime - the output starts on violating the disarmed zones for which the “chime” option
has been activated. Operation of the output can be restricted to the selected "list of
zones" or to specified partition (identically as for the 01 output type). The output
can remain active for a specified time (from 01 to 99 seconds or from 01 to 99
minutes).
If the LATCH option (on until switch-off) is enabled for the output, it will
be deactivated when the alarm is cleared by the user. The output signals violations
irrespective of whether the chime blocking in the keypad is on or off (to enable the
blocking, press and hold down the key [8]).
12 - switch MONO - the output is activated by calling the user function 7 ([CODE][
*
][7]) or
using a code with authority level 5 ([CODE][#]). Operation of the output can be
restricted to specified partition. The output can remain active for a time from 01 to
99 seconds or from 01 to 99 minutes (do not program the LATCH option for the
output).
13 - switch BI (ON/OFF) - the output changes its state when the user function 8
([CODE][
*
][8])
is called or a code with authority level 6 ([CODE][#]) is used.
Operation of the output can be restricted to specified partition.
14 - arm status - the output is active in the armed mode. Operation of the output can be
restricted by selecting a "list of zones" or partition. Unless zones and partitions are
selected, the output is active when any partition (zone) is armed.
15 - silent arm status - the output is active in the silent armed mode. Operation of the
output can be restricted by selecting a "list of zones" or specific partitions.
16 - exit delay status - the output is active during the "exit delay" countdown by the control
panel. Operation of the output can be limited to indicating the "exit delay" for
specified partition.
17 - entry delay status - the output is active during the "entry delay" countdown. Operation
of the output can be limited to selecting the "entry delay" for specified partition.