MAGENTA
DIGITAL GLASS-BREAK DETECTOR
magenta_en 03/13
The MAGENTA detector enables detection of plate, tempered or laminated glass breaking.
The detector will report the alarm when a low frequency sound (impact) followed by a high
frequency sound (glass-break) are registered. The high-frequency channel is analyzed for
four seconds from receiving the low-frequency sound wave.
1. Features
Advanced dual path signal analysis.
Stepless regulation of detection sensitivity.
Low supply voltage signaling (voltage drop below 9 V ±5%).
LED indicator.
Tamper protection in 2 ways – cover removal and tearing enclosure from the wall.
2. Electronics board
terminals:
+12V - power input +12 V DC (±15%);
COM - common ground;
TMP - tamper output (NC),
NC - alarm output (NC).
tamper contact.
red color LED to indicate
detection of low-frequency sound – ON for 0,5 seconds;
alarm – ON for 2 seconds;
test mode – short flash every 3 seconds;
low supply voltage – ON.
detector configuration pins:
TEST – enabling/disabling the test mode. In the test
mode, the detector reports an alarm when it detects a
high frequency sound. The INDIGO TESTER is
recommended to test the detector. The test mode is
enabled when the jumper is set in ON position (Fig. 2).
LED – enabling/disabling the LED indicator. The LED
indicator is enabled when the jumper is set in ON
position (Fig. 3).
potentiometer for the adjustment of detection sensitivity
(Fig. 4).

Other manuals for Satel MAGENTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Satel MAGENTA and is the answer not in the manual?

Satel MAGENTA Specifications

Power IconPower
supply voltage12 V DC ±15%
standby current consumption5 mA
maximum current consumption10 mA
Performance IconPerformance
relay contacts rated load40 mA / 16 V DC
alarm signaling time2 s
detection rangeup to 6 m
Operating Environment IconOperating Environment
environmental class according to EN50130-5II
operating temperature range-10 to +55 °C
enclosure dimensions26 x 112 x 29 mm
Weight and Dimensions IconWeight and Dimensions
weight40 g