3.3.1 Configuring a recording cycle
The administrator can activate or de-activate the recording cycle.
Figure 13 : Recording cycle off
Figure 14 : Recording cycle on
Ö Recording period: time in seconds between two consecutive recordings. This time
must be between 1 second and 255 seconds. The recording duration can then be
established.
Ö Recording duration: total time (in minutes) of the measurement recording cycle. The
number of measurements to be recorded during the cycle corresponds to:
Period
ionCycleDurat
asuresNumberOfMe
60
×
=