Operator's Manual: Models Saturn™ 140 & Saturn™ 230
3-6
Figure 3E - Burner Nozzle and Electrode Specifications
Installing the Burner
Checking the Burner Nozzle and Electrodes
NOTE: The burner nozzle is factory installed. Both furnace models use a Delavan 9-5 nozzle. The nozzle
size is indicated on the nozzle as shown in Figure 3E. Refer also to Appendix A at the back of the manual for
additional specifications/instructions on the burner nozzle.
ATTENTION: Check the electrode settings as specified in Figure 3E. The electrode settings must be correct
for your burner to operate properly.
BURNER NOZZLE
NOZZLE IS STAMPED EITHER 9−5
OR −5 ON FLAT OF NOZZLE HEAD
SIDE VIEW − AA
3/16" GAP BETWEEN
ELECTRODES & NOZZLE
CRITICAL DIMENSION:
NOZZLE MUST BE 1/8"
AHEAD OF THE DISK.
NOZZLE MUST NOT BE
BEHIND THE DISK.
1/8"
SPARK
GAP
SIDE VIEW − BB
V
I
E
W
A
A
V
I
E
W
B
B
3X
I88340

Table of Contents