Be careful that the oil tank may not run out
of oil completely.
In that case, even though oil is supplied,
air may get in. As a result, ignition failure or
operation failure may occurs.
Untighten the screw for exhaust in the oil
lter by a screwdriver, the air goes out.
When oil ows out, please tighten it.
(This is possible only in case that the oil
tank is above the oil lter.)
If the oil tank is below the oil lter or the air
ows out enough like the above, lock the
screw for exhaust and remove the air with
the exhaust valve.
In such case, open the exhaust valve turn
the power on to operate the boiler.
After about 6-7 Seconds, the electronic
pump exhaust the air o with noise,
and CHECK lamp on, the boiler stops.