52
PRINT
ACCUMULATION
TARE
The scale does not print
• Another printout is already in progress (busy)
• Make sure there is a roll in the printer
• The printer does not switch on
• The weight is unstable (unStAb)
• The net or gross weight is negative or is insufficient for printing (loW)
• Underload or overload (______ o
------
) (un.oVEr)
• The scale was not loaded after the last printing (no.0.unS)
• You are trying to print a non-approved weight
The scale does not accumulate
• Make sure there is a roll in the printer
• The printer does not switch on
• The weight is unstable (unStAb)
• The net or gross weight is negative (loW)
• Underload o overload (______ o ------) (un.oVEr)
• The scale was not unloaded after the last printing (no.0.unS)
• The weight is insufficient for weighing (loW)
- less than 10 divisions for the accumulator modes
- less than “Min” for the approved products (shown on the measuring plate)
The scale does not tare
• The weight is unstable (unStAb)
• The gross weight is negative (loW)
• The weight is insufficient
• The weight exceeds the maximum capacity
• The tare function has been deactivated (see page 49)
• In the event of manual tare, the value exceeds the maximum capacity
The sale has lost the total
• Switching off the scale causes the accumulated totals to be lost
NU2-IPC20_50-E-0918