EasyManua.ls Logo

Scale Computing HC3 - Racking

Scale Computing HC3
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1004/2018
HC1150 Idle Load Startup Staging
Watts 99.3 116.83 136.1 13.95
Amps 0.84 0.954 1.106 0.89
kVA 0.0993 0.11683 0.1361 0.01395
BTU/hr 358.81 398.62 464.37 47.60
Test Voltage 120.2 120.4 119.95 120.93
HC1150D* Idle Load Startup Staging
Watts 163.5 164.6 184.3 10.7
Amps 1.363 1.363 1.195 0.085
kVA 0.1635 0.1646 0.1843 0.0107
BTU/hr 557.86 561.62 628.83 36.51
Test Voltage 119.6 119.8 119.3 120.1
HC1150DF* Idle Load Startup Staging
Watts 163.5 164.6 184.3 10.7
Amps 1.363 1.363 1.195 0.085
kVA 0.1635 0.1646 0.1843 0.0107
BTU/hr 557.86 561.62 628.83 36.51
Test Voltage 119.6 119.8 119.3 120.1
Racking
Watch this 2 minute video on our Youtube Channel for step-by-step assistance in racking your HC1100
Series node. And yes, it’s really that easy.
Hardware and Power Specications
* The HC1150D and HC1150DF are approximate and may vary by
10 to 15 Watts depending on various upgrades and options.