4
Scan 66 Technical data Unit
CO Emission at 13% O
2
0,029 %
CO Emission at 13% O
2
367 mg/Nm
3
Dust @ 13% O
2
27 mg/Nm
3
No
x
@ 13% O
2
85 mg/Nm
3
Efficiency 78 %
Nominel output 5 kW
Chimney temperature EN 13240 302 °C
Amount of smoke 5,0 g/sek
Sub-pressure EN 13240 12 Pa
Recommended sub-pressure in connecting piece 16 - 18 Pa
Required combustion air supply 10,2 m
3
/h
Fuel Wood
Fuel consumption 1,72 kg/h
Amount of fuel 1,3 kg
Technical data and dimensions
Materials: ...............Steel plate, cast iron, galvanised sheet, vermicolite
Surface treatment: ........................................................................... Senotherm
Max. wood length: ..................................................................................... 33 cm
Weight Scan 66 series: ............................................................... ca. 90-100 kg
Connecting piece internal diameter: ............................................... 144 mm
Connecting piece external diameter: .............................................. 148 mm
Approval type: ................................................................ Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other
words, you should let the fire die down until only the embers are left,
before refuelling.
The Scan 66 - series was build in compliance with the homologized
product type specified in the Assembly- and Instructions Manual
provided with the product.
The DoP declaration of performance is available from scan.dk
Test in compliance with EN 13240
TECHNICAL DATA
Please note:
You get the best use of the stove by using a
”top-down lighting”, see page 28.