Compressor Controller
MAM – 200
OPERATION MANUAL
Revision 1.0
04.08.2017

Questions and Answers

  • R
    Roberto MooreAug 19, 2025
    What to do if my SCC MAM–200 Controller shows OVERLOAD?
    • A
      Annette SmithAug 20, 2025
      If your SCC Controller displays 'OVERLOAD', it could be due to several reasons such as low voltage, blocked tubes, worn bearings, mechanical failure, or incorrect data settings. To resolve this, verify the set data, voltage, bearings, tubes, and other components.
  • M
    mcgeejeffreyAug 21, 2025
    How to fix a SHORT CIRCUIT error on my SCC Controller?
    • K
      Karen SchultzAug 22, 2025
      If the SCC Controller displays 'SHORT CIRCUIT', it's likely due to incorrect cable connections or incorrect data settings. You should check the wiring and ensure the data is set correctly.
  • S
    Samantha RubioAug 25, 2025
    What causes LACK PHASE error on SCC Controller?
    • B
      Breanna OlsonAug 25, 2025
      If the SCC Controller shows 'LACK PHASE', this indicates a missing power phase or a damaged contactor. Inspect the power supply and contactors terminal to troubleshoot.
  • S
    stevensonnormaAug 26, 2025
    Why is my SCC MAM–200 showing a BLOCK error?
    • A
      Austin HahnAug 26, 2025
      If the SCC Controller displays 'BLOCK', it might be due to low voltage, blocked tubes, worn bearings, mechanical failure, or incorrect set data. Check the set data, voltage, bearings and tubes.
  • O
    Olivia SullivanAug 27, 2025
    How to troubleshoot an UNBALANCE error on SCC MAM–200?
    • D
      David CastroAug 27, 2025
      If the SCC Controller displays 'UNBALANCE', the cause may be power unbalance or a damaged contactor. You should check the power supply, contactors, and the motor.
  • R
    Robert DavisAug 30, 2025
    What does AIR P HIGH mean on my SCC MAM–200 Controller?
    • B
      Brian WagnerAug 30, 2025
      If your SCC Controller is showing 'AIR P HIGH', it means the pressure is too high or the pressure sensor has failed. Check the pressure and the pressure sensor to resolve this.
  • M
    Michael ClarkAug 31, 2025
    How do I correct a WRONG PHASE SEQUENCE on my SCC MAM–200 Controller?
    • J
      Jennifer StoutSep 1, 2025
      If the SCC Controller displays 'WRONG PHASE SEQUENCE', it's likely due to a reversed phase sequence or a phase being off. You should check the wiring.
  • N
    Nicole KaufmanSep 3, 2025
    What does AIR T HIGH mean on my SCC Controller?
    • P
      proctordouglasSep 3, 2025
      If the SCC Controller indicates 'AIR T HIGH', it could be due to poor ventilation or insufficient lubricant. Inspect the vent condition and the lubricant amount.
  • O
    ochoawalterSep 4, 2025
    What should I do if my SCC Controller says LACK WATER?
    • L
      Leslie ArnoldSep 5, 2025
      If the SCC Controller reports 'LACK WATER', the water pressure switch might be damaged. You should check the water pressure switch.
  • S
    smithmarySep 6, 2025
    How to resolve AIR P SENSOR FAULT on SCC MAM–200 Controller?
    • K
      Katherine MitchellSep 7, 2025
      If your SCC Controller displays 'AIR P SENSOR FAULT', it could be due to a disconnected cable, a damaged sensor, or the cable being connected in reverse. Check the wiring and the sensor.

Summary

Compressor Controller MAM-200 Operation Manual

Important Notices

Key operational notices and safety precautions for the compressor controller.

Basic Operations

Button Explanation

Detailed explanation of the function of each button on the controller interface.

Status Display and Operations

Operating Parameters and Menu Navigation

Calendar Functionality

Custom Parameters

Parameter View and Modification

Process for viewing and modifying custom parameters, including password entry.

Parameter Table and Functions

Detailed table of customer parameters, their preset values, and functions.

Factory Parameters

Operating Authorization and Password

Controller Functions and Technical Parameters

Motor Protection Overview

Details on short circuit, block, overload, and phase protection for the motor and fan.

Model and Specification

Electrical Wiring Installation

Alarm Functions

Monitor Text and Specific Alarms

Details on specific alarms like Air Filter, Oil Filter, O/A, Lubricating Oil, and Grease.

Controller Protection

Motor Protection Details

Details on short circuit, block, overload, lack phase, and unbalance protection for the motor.

Air Temperature Protection

Protection against high air temperature, triggering an alarm and machine stop.

Air Compressor Reversal Protection

Protection against incorrect phase sequence causing the motor to not start.

Air Pressure Protection

Protection against high air pressure, triggering an alarm and machine shutdown.

Sensor Failure Protection

Protection against pressure or temperature sensor failures, causing alarm and stop.

Interlock Protection

Protection when fan does not run despite high exhaust temperature.

Troubleshooting

Fault Diagnosis Method

Steps to check faults and history faults via the 'RUN PARAMETER' and 'CURRENT FAULT' menus.

Sequence Mode Control and Network

Sequence Mode Operation

Details on how the MAM-860 controller operates with other MAM series compressors in a network.

Setting the Master Unit

Procedure for configuring the controller to operate as a master unit in sequence mode.

Setting the Slave Unit

Procedure for configuring the controller to operate as a slave unit in sequence mode.

Sequence Start and Stop Control

How master controls compressor activation and deactivation in sequence mode.

Sequence Communication Monitoring

Methods to check received and sent messages in sequence or COM mode.

Network Communication Protocol

Details on MODBUS RTU support, baud rate, and communication parameters.